beautypg.com

Fcoe-1024, Fcoe-1029, Fcoe-1030 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 200

background image

184

Network OS Message Reference

53-1003227-01

FCOE-1024

8

FCOE-1024

Message

FDISC received from Enode without prior FLOGI.

Message Type

DCE

Severity

WARNING

Probable Cause

Indicates that a fabric discovery (FDISC) frame is received from the end node that has not logged in. The
end node must send a fabric login (FLOGI) before it can send an FDISC.

Recommended

Action

No action is required.

FCOE-1029

Message

Version mismatch between FIP FDISC and root VN port.

Message Type

DCE

Severity

WARNING

Probable Cause

Indicates that the FCoE Initialization Protocol (FIP) version does not match between the fabric login
(FLOGI) and fabric discovery (FDISC) frames.

Recommended

Action

Make sure that the device that is trying to log in conforms to the FC-BB-5 standard.

FCOE-1030

Message

Version mismatch between FIP LOGO and root VN port.

Message Type

DCE

Severity

WARNING

Probable Cause

Indicates that the switch received an FCoE Initialization Protocol (FIP) logout (LOGO) request but the
device logged in with a different FIP version.

Recommended

Action

Make sure that the device that is trying to log in conforms to the FC-BB-5 standard.