53-1003227-01

BL-1022

8

BL-1022

Message

Init Failed: Switch DISABLED because internal ports were not ONLINE,

internal port number not ONLINE>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the switch initiation failed because one or more of the internal ports were not online. The
switch is faulted.

Recommended

Action

Reload or power cycle the switch.

Execute the diag systemverification command to verify that the switch does not have hardware
problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

Additional fault messages precede and follow this error providing more information. Refer to other error
messages for recommended action.

If the message persists, replace the switch.

BL-1023

Message

Interface module in was reset before initialization completed. As a

result the interface module is faulted.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the interface module was reset before the initialization completed.

Recommended

Action

Reload or power cycle the interface module using the power-off and power-on commands. If the
message persists, replace the interface module.

BL-1024

Message

All ports on the interface module in will be reset as part of the

firmware upgrade.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a recent firmware upgrade caused the interface module firmware to be upgraded and
resulted in a cold upgrade. As part of the upgrade, all data path elements were reset.

Recommended

Action

No action is required.