beautypg.com

Fvcs-2002, Fvcs-2003, Fvcs-2004 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 216

background image

200

Network OS Message Reference

53-1003227-01

FVCS-2002

8

FVCS-2002

Message

Link State Update sent to Remote RBridge Failed - reason ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a possible cluster infrastructure problem.

Recommended

Action

Execute the show fabric isl command to check the cluster connection status.

If the message persists, execute the copy support command and contact your switch service provider.

FVCS-2003

Message

Lag Configureation Update sent to Remote RBridge Failed - reason (

Code>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a possible cluster infrastructure problem.

Recommended

Action

Execute the show fabric isl command to check the cluster connection status.

If the message persists, execute the copy support command and contact your switch service provider.

FVCS-2004

Message

FCS Commit stage Failed - cfg type , cfg tag

Tag>, domain , reason ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the fabric configuration server (FCS) commit stage has failed. The failure reason can be
one of the following:

7 - Memory allocation error

14 - Reliable Transport Write and Read (RTWR) send failure

Recommended

Action

Check the status of the virtual link aggregation group (vLAG) identified by the configuration tag.

If the message persists, execute the copy support command on both this RBridge and the remote
RBridge specified by the domain field and contact your switch service provider.