C2 messages, C2-1004, C2-1006 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 132: C2-1007

116
Network OS Message Reference
53-1003227-01
C2-1004
8
C2 Messages
C2-1004
Message
S
good_addr:0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the interface
module.
C2-1006
Message
S
faults identified, continuing to monitor for errors: fault1:
fault2:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that some internal link errors have been detected. These errors can be normal in an active
running system.
The system automatically starts a more detailed monitoring of the errors reported in the internal
hardware. There is no action required by the user at this time. If any actual hardware failures are
detected, the C2-1010 message will be generated identifying the failing field-replaceable unit (FRU).
Recommended
Action
No action is required.
C2-1007
Message
S
change, best effort QoS will be turned off automatically as it is no longer
supported under this configuration.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that quality of service (QoS) will be turned off automatically at next port state change because
best effort is no longer supported on 4 Gbps or 8 Gbps platform long distance ports.