8

FABS-1005

Message

(= ).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an unsupported operation has been requested. This is usually an internal Network OS
problem or file corruption. The following is the possible value for the function name and description of
problem
variable:

fabsys_write: Unsupported write operation: process xxx

The xxx value is the process ID (PID), which could be any whole number.

Recommended

Action

Reload or power cycle the active management module (for modular systems) or the switch (for compact
systems).

If the message persists, execute the firmware download command to update the firmware.

FABS-1006

Message

: object unit .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there is no device in the slot with the specified object type ID in the system module record.
This could indicate a serious Network OS data problem on the switch. The following are the possible
values for the function name and description of problem variable:

setSoftState: bad object

setSoftState: invalid type or unit

media_sync: Media oid mapping failed

fabsys_media_i2c_op: Media oid mapping failed

fabsys_media_i2c_op: obj is not media type

media_class_hndlr: failed sending media state to blade driver

Recommended

Action

If the message is isolated, monitor the error messages on the switch. If the error is repetitive or if the
fabric failed, fail over or reload the switch.