122

Network OS Message Reference

53-1003227-01

CBR-1001

8

CBR Messages

CBR-1001

Message

Port port fault. Change the SFP or check the cable.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.

Recommended

Action

Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.

CBR-1002

Message

Port chip faulted due to internal error.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error. All the ports on the interface module or switch will be disrupted.

Recommended

Action

For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.