Bll messages, Bll-1000 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 131
Network OS Message Reference
115
53-1003227-01
BLL-1000
8
BLL Messages
BLL-1000
Message
ASIC driver detected code>). Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that an interface module regulation problem was reported on the specified slot. The interface The reason codes are as follows: • 1 = Available buffer overflow • 2 = Backend port buffer timeout • 3 = Backend port got shut down • 4 = Embedded port buffer timeout • 5 = Excessive busy mini buffer • 6 = Excessive RCC VC on E_Port • 7 = Excessive RCC VC on FL_Port • 8 = Fail detection buffer tag error • 9 = Fail detection TX parity error • 10 = EPI CMEM interrupt error • 11 = Checkpoint Middleware Interface (CMI) interrupt error • 12 = Interrupt overrun • 13 = FDET interrupt • 14 = Interrupt suspended • 15 = Filter LISTD error • 16 = Unknown filter LIST error • 17 = Wait for LPC open state • 18 = Wait for Old port state • 19 = Wait for Open init state • 20 = TX parity error • 21 = RAM parity error • 22 = Built in Self Repair (BISR) or RAMINIT error Recommended Action Make sure the interface module is seated correctly. If the interface module is seated correctly, reload or Execute the diag systemverification command to verify that the interface module does not have If the message persists, replace the interface module.
module is faulted.
power cycle the interface module using the power-off and power-on commands.
hardware problems.