beautypg.com

Nsm-1021, Nsm-1022, Nsm-1023 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 319

background image

Network OS Message Reference

303

53-1003227-01

NSM-1021

8

NSM-1021

Message

Interface IP overlap with management IP ifname:.

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates that the IP address configured on the interface overlaps with the management IP address.

Recommended

Action

Change the interface IP address using the ip address command.

NSM-1022

Message

FCoE configuration has been

Message Type

DCE

Severity

INFO

Probable Cause

Indicates that the Fibre Channel over Ethernet (FCoE) configuration has been enabled or disabled on the
specified interface.

Recommended

Action

No action is required.

NSM-1023

Message

RBridge ID has joined Port-channel . Port-channel is a

vLAG with RBridge IDs .

Message Type

DCE

Severity

INFO

Probable Cause

Indicates that the specified RBridge has joined the virtual link aggregation group (vLAG).

Recommended

Action

No action is required.