FSS-1004

8

FSS-1004

Message

FSS out of memory ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the system ran out of memory.

Recommended

Action

Check memory usage on the switch using the show process memory command.

Execute the copy support command and contact your switch service provider.

FSS-1005

Message

FSS read failure.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the read system call to the fabric synchronization service (FSS) device has failed.

Recommended

Action

If the message persists, execute the copy support command and contact your switch service provider.

FSS-1006

Message

No FSS message available.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that data is not available on the fabric synchronization service (FSS) device.

Recommended

Action

If the message persists, execute the copy support command and contact your switch service provider.