Hlo messages, Hlo-1001, Hlo-1002 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 268
252
Network OS Message Reference
53-1003227-01
HLO-1001
8
HLO Messages
HLO-1001
Message
Incompatible Inactivity timeout
value
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates that the hello (HLO) message was incompatible with the value specified in the fabric shortest
path first (FSPF) protocol. The Brocade switch will not accept FSPF frames from the remote switch.
In the Network OS, the HLO dead timeout value is not configurable, so this error can only occur when the
Brocade switch is connected to a switch from another manufacturer.
Recommended
Action
The dead timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to the documentation for the other manufacturer's switch to change this value.
HLO-1002
Message
Incompatible Hello timeout
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates that the hello (HLO) message was incompatible with the value specified in the fabric shortest
path first (FSPF) protocol. The Brocade switch will not accept FSPF frames from the remote switch.
In the Network OS, the HLO timeout value is not configurable, so this error can only occur when the
Brocade switch is connected to a switch from another manufacturer.
Recommended
Action
The HLO timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to the documentation for the other manufacturer's switch to change this value.