Em-1033, Em-1034, Em-1036 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 175

background image

Network OS Message Reference

159

53-1003227-01

EM-1033

8

EM-1033

Message

MM in is reloading.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the standby management module has been detected to be in the reload process. The high
availability (HA) feature will not be available. This message occurs every time the other management
module reloads, even as part of a clean warm failover. In most situations, this message is followed by the
EM-1047 message, and no action is required for the management module; however, if the failover was
not intentional, it is recommended to find the reason for the failover.

Recommended

Action

If the standby management module was just reloaded, wait for the error to clear (execute the show slots
command to determine if the errors are cleared). Watch for the EM-1047 message to verify that this error
has cleared.

If the standby management module state changes to faulty or if it was not intentionally reloaded, check
the error logs on the other management module (using the show logging raslog command) to
determine the cause of the error state.

Reseat the field-replaceable unit (FRU). If the problem persists, replace the FRU.

EM-1034

Message

is set to faulty, rc=.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.

Recommended

Action

Reseat the FRU.

Execute the diag systemverification command to verify that the switch does not have hardware
problems.

If the problem persists, replace the FRU.

EM-1036

Message

is not accessible.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified field-replaceable unit (FRU) is not present on the switch.

If the FRU is a Chassis ID (CID) card, then the default WWN and IP addresses are used for the switch.