beautypg.com

Em-1011, Em-1012, Em-1013 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 170

background image

154

Network OS Message Reference

53-1003227-01

EM-1011

8

EM-1011

Message

Received unexpected power down for , but cannot determine if it has power.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, after 4 seconds it could not be determined if it has
powered down or not.

Recommended

Action

Reseat the interface module. If the problem persists, replace the interface module.

EM-1012

Message

failed state transition, unit faulted.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that a switch interface module or compact switch failed to transition from one state to another. It
is faulted. The specific failed target state is displayed in the message. There are serious internal Network
OS configuration or hardware problems on the switch.

Recommended

Action

Reload or power cycle the switch.

Execute the diag systemverification command to verify that the switch does not have hardware
problems.

If the problem persists, replace the FRU.

EM-1013

Message

Failed to update FRU information for .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the environmental monitor (EM) was unable to update the time alive or original equipment
manufacturer (OEM) data in the memory of an field-replaceable unit (FRU).

Recommended

Action

The update is automatically attempted again. If it continues to fail, reseat the FRU.