BL-1016

8

BL-1016

Message

Interface module port in failed to enable.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the specified interface module port could not be enabled.

Recommended

Action

Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload
or power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have
hardware problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

If the message persists, replace the interface module.

BL-1017

Message

Initializing.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified slot has started initializing the ports.

Recommended

Action

No action is required.

BL-1018

Message

Initialization completed.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified slot has completed initializing the ports.

Recommended

Action

No action is required.