beautypg.com

Trce-1006, Trce-1007, Trce-1008 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 447

background image

Network OS Message Reference

431

53-1003227-01

TRCE-1006

8

TRCE-1006

Message

FTP Connectivity Test succeeded to FTP site ' '.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a connectivity test to the FTP host has succeeded.

Recommended

Action

No action is required.

TRCE-1007

Message

Notification of this MM has failed. Parameters temporarily out of sync with other

MM.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the active management module was unable to alert the standby management module of a
change in the trace status. This message is only applicable to modular switches.

Recommended

Action

This message is often transitory. Wait a few minutes and try the command again.

If the message persists, execute the copy support command and contact your switch service provider.

TRCE-1008

Message

Unable to load trace parameters.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the management module is unable to read the stored trace parameters.

Recommended

Action

Reload the switch or the chassis.

If the message persists, execute the copy support command and contact your switch service provider.