EM-1014

8

EM-1014

Message

Unable to read sensor on ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1015

Message

Warm recovery failed ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a warm boot.

Recommended

Action

Monitor the switch. If the problem persists, reload or power cycle the switch.

EM-1016

Message

Cold recovery failed ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a cold boot.

Recommended

Action

Monitor the switch. If the message persists, execute the copy support command and contact your
switch service provider.