beautypg.com

Ktrc-1004, Ktrc-1005 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 278

background image

262

Network OS Message Reference

53-1003227-01

KTRC-1004

8

KTRC-1004

Message

Cannot write to ATA dump device.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the write boundary in the advanced technology attachment (ATA) dump device has been
exceeded.

Recommended

Action

Execute the copy support command and reload the switch. If the problem persists, contact your switch
service provider.

KTRC-1005

Message

Trace initialization failed. .

code>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that trace was unable to initialize.

Recommended

Action

Execute the copy support command and reload the switch. If the problem persists, contact your switch
service provider.