beautypg.com

Em messages, Em-1001, Em-1002 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 167: Em-1003

background image

Network OS Message Reference

151

53-1003227-01

EM-1001

8

EM Messages

EM-1001

Message

is overheating: Shutting down.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that a field replaceable unit (FRU) is shutting down due to overheating. Overheating is mainly
due to a faulty fan and can also be caused by the switch environment.

Recommended

Action

Verify that the location temperature is within the operational range of the switch.

Execute the show environment fan command to verify that all fans are running at normal speeds.
Replace fans that are missing or not performing at high enough speeds.

EM-1002

Message

System fan(s) status .

Message Type

LOG | FFDC

Severity

INFO

Probable Cause

Indicates that a compact system has overheated and may shut down. All the fan speeds are dumped to
the console.

Recommended

Action

Verify that the location temperature is within the operational range of the switch.

Execute the show environment fan command to verify that all fans are running at normal speeds.
Replace fans that are missing or not performing at high enough speeds.

EM-1003

Message

has unknown hardware identifier: FRU faulted.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that a field-replaceable unit (FRU) header cannot be read or is invalid. The FRU is faulted.

Recommended

Action

Reload or power cycle the switch.

Execute the diag systemverification command to verify that the switch does not have hardware
problems.