beautypg.com

Trce-1009, Trce-1010, Trce-1011 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 448

background image

432

Network OS Message Reference

53-1003227-01

TRCE-1009

8

TRCE-1009

Message

Unable to alert active MM that a dump has occurred.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby management module is unable to communicate trace information to the active
management module. This message is only applicable to modular switches.

Recommended

Action

Execute the show ha command to verify that the current management module is standby and the active
management module is active.

If the message persists, execute the copy support command and contact your switch service provider.

TRCE-1010

Message

Traced fails to start.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the trace daemon (traced), which is used for transferring the trace files has failed to start.
The trace capability within the switch is unaffected. The system automatically restarts the traced facility
after a brief delay.

Recommended

Action

If the message persists, reload the switch or the chassis.

Execute the copy support command and contact your switch service provider.

TRCE-1011

Message

Trace dump manually transferred to target '

slot the trace dump is transferred> ': .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the trace dump files were transferred manually to the specified slot.

Recommended

Action

No action is required.