Trce-1009, Trce-1010, Trce-1011 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 448

432
Network OS Message Reference
53-1003227-01
TRCE-1009
8
TRCE-1009
Message
Unable to alert active MM that a dump has occurred.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby management module is unable to communicate trace information to the active
management module. This message is only applicable to modular switches.
Recommended
Action
Execute the show ha command to verify that the current management module is standby and the active
management module is active.
If the message persists, execute the copy support command and contact your switch service provider.
TRCE-1010
Message
Traced fails to start.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the trace daemon (traced), which is used for transferring the trace files has failed to start.
The trace capability within the switch is unaffected. The system automatically restarts the traced facility
after a brief delay.
Recommended
Action
If the message persists, reload the switch or the chassis.
Execute the copy support command and contact your switch service provider.
TRCE-1011
Message
Trace dump manually transferred to target ' slot the trace dump is transferred> ': Message Type LOG Severity INFO Probable Cause Indicates that the trace dump files were transferred manually to the specified slot. Recommended Action No action is required.