EM-1029
8
EM-1029
Message
Operational status (
access is being retried.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the inter-integrated circuit (I2C) bus had problems and a timeout occurred.
Recommended
Action
This is often a transient error.
Watch for the EM-1048 message, which indicates that the problem has been resolved.
If the error persists, check for loose or dirty connections. Remove all dust and debris prior to reseating
the field-replaceable unit (FRU). Replace the FRU if it continues to fail.
EM-1031
Message
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the environmental monitor (EM) has found a switch interface module that is inserted, but
the optical ejector switch is not latched. The interface module in the specified slot is treated as not
inserted.
Recommended
Action
Close the ejector switch (completely screw in the optical (middle) thumbscrew on the switch fabric
module (SFM)) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate Hardware
Reference Manual for instructions on inserting the switch interface modules.
EM-1032
Message
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates that the interface module in the specified slot has been marked as faulty because the
peripheral component interconnect (PCI) scan during interface module validation failed.
Recommended
Action
Power cycle or reseat the interface module.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
If the problem persists, replace the interface module.