beautypg.com

Eanv-1004, Eanv-1005, Eanv-1006 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 165

background image

Network OS Message Reference

149

53-1003227-01

EANV-1004

8

EANV-1004

Message

C: Invalid DMA ch pointer, chan:, good_addr:0x

address> bad_addr:0x.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

No action is required. The software will recover from the error.

EANV-1005

Message

C,A: Memory allocation failed.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates memory allocation failure in the software.

Recommended

Action

Reload the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.

EANV-1006

Message

C: HW ASIC Chip fault. Type = 0x, Error =

string>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the
chip not operational.

Recommended

Action

Reload the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.