Ts messages, Ts-1002, Ts-1008 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 450
434
Network OS Message Reference
53-1003227-01
TS-1002
8
TS Messages
TS-1002
Message
configured>: locl: 0x clock server>. Message Type LOG Severity INFO Probable Cause Indicates that the switch time synchronization was sourced from an alternate clock server instead of the • LOCL - Local switch clock. • External - External Network Time Protocol (NTP) server address configured. This message may be logged during temporary operational issues such as IP network connection issues Recommended Action Execute the show ntp status command to verify that the switch clock server IP address is configured TS-1008 Message System time changed from Message Type LOG Severity INFO Probable Cause Indicates that the source of switch time synchronization was changed to another configured clock server Recommended Action No action is required. New clock server synchronization will adjust the clock time.
configured clock server. The clock server used can be one of the following type:
to the external clock server. If the message does not recur, it can be ignored.
correctly. Verify if this clock server is accessible to the switch and functional. If it is not accessible or
functional, configure an accessible and functional clock server or reset the clock server to local clock
server (LOCL).
because the Network Time Protocol (NTP) query to the current active external clock server failed.