Network OS Message Reference

53-1003227-01

C2-1011

8

C2-1011

Message

S,P (): Primitive received with

Encoding errors, do AL_RESET.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates encoding errors on the internal links. This error can cause cyclic redundancy check (CRC)
errors or frame loss.

Recommended

Action

Whenever the error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, check the backplane or replace the
interface module.

C2-1012

Message

S,P (): Link Timeout on

internal port ftx= tov= (>

timeout value>), interface module may need to be reset or replaced.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that above normal errors were observed in hardware that may or may not impact the data
traffic.

Recommended

Action

Whenever the error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.