Em-1051, Em-1059, Em-1064 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 179

background image

Network OS Message Reference

163

53-1003227-01

EM-1051

8

EM-1051

Message

: Inconsistency detected, FRU re-initialized.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that an inconsistent state was found in the specified field-replaceable unit (FRU). This event
occurs when the state of the FRU was changing during a failover. The FRU is reinitialized and traffic may
have been disrupted.

Recommended

Action

No action is required.

EM-1059

Message

with ID may not be supported on this

platform, check firmware version as a possible cause.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the interface module inserted in the specified slot or the switch (for compact switches) is
not compatible with the switch configuration software. The interface module will not be completely
usable.

The interface module may only be supported by a later (or earlier) version of the firmware.

Recommended

Action

Change the management module firmware or replace the interface module. Make sure the replacement
is compatible with your switch type and firmware.

EM-1064

Message

is being powered off (based on user configuration) upon receiving a HW

ASIC ERROR, reason:.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the interface module has been powered off because a hardware application-specific
integrated circuit (ASIC) error was detected, and you have selected to power off the problem interface
module when such a condition occurred.

Recommended

Action

Execute the copy support command and contact your switch service provider.