Bl-1003, Bl-1004, Bl-1006 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 118
102
Network OS Message Reference
53-1003227-01
BL-1003
8
BL-1003
Message
Faulty interface module in
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates a faulty interface module in the specified slot.
Recommended
Action
Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload
or power cycle the interface module using the power-off and power-on commands.
Execute the diag systemverification command to verify that the interface module does not have
hardware problems.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
If the message persists, replace the interface module.
BL-1004
Message
Suppressing interface module fault in
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the specified interface module experienced a failure but was not faulted due to a user
setting.
Recommended
Action
Reload or power cycle the interface module using the power-off and power-on commands.
Execute the diag systemverification command to verify that the interface module does not have
hardware problems.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
If the message persists, replace the interface module.
BL-1006
Message
Interface module
experienced abrupt failure.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the errors (mostly synchronization errors) on this interface module are harmless. Probably,
the standby management module connected to the active management module has experienced
transitory problems.