BL-1003

8

BL-1003

Message

Faulty interface module in .

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates a faulty interface module in the specified slot.

Recommended

Action

Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload
or power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have
hardware problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

If the message persists, replace the interface module.

BL-1004

Message

Suppressing interface module fault in .

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the specified interface module experienced a failure but was not faulted due to a user
setting.

Recommended

Action

Reload or power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have
hardware problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

If the message persists, replace the interface module.

BL-1006

Message

Interface module NOT faulted. Peer interface module

experienced abrupt failure.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the errors (mostly synchronization errors) on this interface module are harmless. Probably,
the standby management module connected to the active management module has experienced
transitory problems.