beautypg.com

Nsm-1037, Nsm-1038, Nsm-1039 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 324

background image

308

Network OS Message Reference

53-1003227-01

NSM-1037

8

NSM-1037

Message

Interface is administratively down due to 1Gbps link configured on

Brocade Trunk.

Message Type

DCE

Severity

INFO

Probable Cause

Indicates that the specified interface has gone down because a 1 Gbps link has been configured on the
Brocade trunk.

Recommended

Action

Remove the 1 Gbps link from the Brocade trunk or change the 1 Gbps small form-factor pluggable (SFP)
transceiver.

NSM-1038

Message

Private VLAN mode changed from to for interface

.

Message Type

DCE

Severity

INFO

Probable Cause

Indicates that the interface private VLAN mode has been changed.

Recommended

Action

No action is required.

NSM-1039

Message

Unsupported Brocade-branded SFP transceiver for interface is

detected.

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates that an unsupported Brocade-branded small form-factor pluggable (SFP) transceiver has been
inserted in the specified interface.

Recommended

Action

Use a Brocade-branded SFP transceiver for the interface because the digital diagnostics will not be
supported.