beautypg.com

Fabr-1039, Fabr-1041, Fabr-1055 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 190

background image

174

Network OS Message Reference

53-1003227-01

FABR-1039

8

Recommended

Action

No action is required.

FABR-1039

Message

Invalid RBridge ID zero received from principal switch (RBridge ID =

RBridge id>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an invalid RBridge ID zero has been received.

Recommended

Action

Check the reason for the principal switch to assign an invalid RBridge ID zero.

FABR-1041

Message

Port is disabled due to trunk protocol error.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a link reset was received before the completion of the trunking protocol on the port.

Recommended

Action

Toggle the port using the no fabric isl enable and fabric isl enable commands.

The port may recover by re-initialization of the link.

If the message persists, execute the copy support command and contact your switch service provider.

FABR-1055

Message

Switch will be taken offline and back online for RBridge Id auto

configuration to take effect.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified switch has been bounced for the RBridge ID auto configuration to take effect
on the unconfigured VCS switch.

Recommended

Action

No action is required.