beautypg.com

Tnld messages, Tnld-1000, Tnld-1001 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 442: Tnld-1005

background image

426

Network OS Message Reference

53-1003227-01

TNLD-1000

8

TNLD Messages

TNLD-1000

Message

TunnelMgr initialized successfully.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Data Center Ethernet (DCE) tunnel manager has been initialized.

Recommended

Action

No action is required.

TNLD-1001

Message

Failed to allocate memory: ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified function has failed to allocate memory.

Recommended

Action

Check the memory usage on the switch using the show process memory command.

Restart or power cycle the switch.

TNLD-1005

Message

TunnelMgr startup failed.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Data Center Ethernet (DCE) tunnel manager encountered an unexpected severe error
during basic startup and initialization.

Recommended

Action

Restart or power cycle the switch.

If the problem persists, download a new firmware version using the firmware download command.