SWCH-1004

8

SWCH-1004

Message

Interface module attach failed during recovery, disabling slot = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified interface module has failed during failover or recovery.

Recommended

Action

For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.

For a compact switch, reload or power cycle the switch.

SWCH-1005

Message

Diag attach failed during recovery, disabling slot = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the diagnostic interface module attach operation has failed during failover or recovery.

Recommended

Action

For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.

For a compact switch, reload or power cycle the switch.

SWCH-1007

Message

Switch port disabled due to \"\".

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified switch port is disabled due to the reason displayed in the message.

Recommended

Action

Take corrective action to restore the port based on the disable reason displayed in the message and then