Bl-1033, Bl-1034, Bl-1037 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 128

background image

112

Network OS Message Reference

53-1003227-01

BL-1033

8

BL-1033

Message

(,bitmap 0x) No disable acknowledgment

from ports (state ). Disabling slot.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the system has timed out waiting for the disable acknowledgment messages from the user
ports.

Recommended

Action

Reload or power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have
hardware problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

If the message persists, replace the interface module.

BL-1034

Message

CEE initialization completed.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified slot has completed initializing the Converged Enhanced Ethernet (CEE)
ports.

Recommended

Action

No action is required.

BL-1037

Message

Faulting chip in , miniS = ,port =

due to BE/BI port fault.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that all ports on the chip have been disabled due to a fault on the chip.

Recommended

Action

Execute the diag systemverification command to determine if there is a hardware error.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.