SYS (Red/Green LED)

When green it indicates that the system voltages are within 5% of their
nominal values. If any of +5V, 3.3V, +12V drop by more than 5%, the
SYS LED turns red. Upon power on it comes up red during a power self
test and turns green when the software executes.

D3, D11

When illuminated, the TA700C has been configured.

TRIG

Indicates that the analyzer has met the trigger condition and is awaiting
for the post-trigger data to be captured.

Jumper Configuration

TA700C +3.3V Power Source selection

TA700C +5V Power Source Selection

Connecting an External Power Supply

Install Shunt 1-2 top to center on JP2 (3.3V)

Install Shunt 1-2 top to center on JP16 (+5V)

Connect the external power supply to JP1 as follows:

This configuration applies +5V power to the TA700C from the external power supply
and redirects the 3.3V power from the on board regulator.

JP2

Shunt 1-2 top to center

+3.3V from on board 5V regulator

Shunt 2-3 bottom to center

+3.3V Bus Power (Default)

JP16

Shunt 1-2 top to center

+5V from external supply

Shunt 2-3 bottom to center

+5V Bus Power (Default)

JP1

JP1.1 Bottom pin

+5VEX

JP1.2 Center pin

+5VEX

JP1.3 Top Pin

GND