Setting the compliance test options, Etting, Ompliance – Teledyne LeCroy TA700_800_850 User Manual User Manual
Page 132: Ptions
Catalyst Enterprises, Inc.
Compliance Device Test
118
Setting the Compliance Test Options
Select the desired device for compliance test and open the Compliance Tests Options
by clicking the Options button.
Figure 106 Compliance Tests Options Selection Dialog Box
Configuration Space Tests Check the device to be tested as Master, Target or both.
Master Protocol Tests
Select protocol test options such as I/O, Memory. For Master test the user
is expected to interact and cause his master card to perform a series of
expected transactions. For the list of these transactions and the order they
appear refer to the “Compliance Test_IUT User Guide.doc”.
Target Protocol Tests
Performs Target tests, in this mode the TA700/800 is a master and
requires little interaction from the user to perform target related tests on
UUT.
DEVSEL# Speed
Select the target DEVSEL# decode speed.
Auto Run
In cases where you would like the test to be performed repetitively, check
the Auto Run box and set the number of times for the test to be repeated.
Click OK to complete setting the options.
Checklist Compatible with Select the PCI specification that you wish the test to follow, PCI 2.1 or
PCI 2.2.
Save Configuration
You may save the test configuration for use later by clicking Save. Assign
a test file name to the configuration and click Save.
Report Mode
When Overview is checked, only test results are displayed, however,
when Detail is checked all details are listed and explained.