Custom Capture Data Project

Catalyst Enterprises, Inc.

95

Timing Analysis - Synchronous

This mode of operation is not supported by the TA700PDC, TA800 or PCI-X.

Make sure that the TA700/800 is in the Timing Analyzer working mode and is
operating in the Advanced Mode as shown on the Main Menu bar below.

Click the Black button on the main menu bar to open the Timing Measurement setup
dialog box below.

Figure 88 Timing Measurement Setup Dialog Box

1. Choose the signals intended for timing violation analysis in the Mask area of

the dialog box and mask each signal that is to be excluded from the analysis.
Alternately you may click the 32 bit or 64 bit button and then uncheck or check
the signals that you want included in the analysis.

2. Set the desired Leading and Trailing edge values in the Parameters area of the

dialog box by either dragging the vertical L and T bars to the desired position
or by using the > >> or < << buttons to position the timing definition bars
incrementally. The >> and << buttons move the bars in 2 ns increments and the
> and < buttons in 0.10 ns increments.