Display Manipulation

Catalyst Enterprises, Inc.

133

Termination Display

In addition to the software determined termination, displayed in the
sample viewer CYCLE column, you may add a column to display a
hardware determined termination.

Note:

This feature is not available for the expansion memory in the TA700.

To display the hardware determined termination: Click the Setup Screen button in an open sample

window to open the Active Signals dialog box.

Figure 119 Active Signals Dialog Box

Click the down arrow next to the Group drop down list box, choose Tools, select
Termination, click Add-> and then OK to include it in the Active Signals list.

Figure 120 Hardware Determined Termination Included in Display

This feature is useful to display a hardware determined termination for cases where,
for some sequencer qualified captures, the software has insufficient data to decode a
termination.

Software determined termination