Gettargetdisconnectoption (pbtargetdisconnect), Setassertframeoption(pbassertframe), Getassertframeoption(pbassertframe) – Teledyne LeCroy TA700_800_850 User Manual User Manual
Page 212: Setmasterabortoption (bmasterabort), Arget, Isconnect, Ption, Omplete, Ransaction, Ssert

Catalyst Enterprises Inc.
Library Exported Interfaces
198
GetTargetDisconnectOption (pbTargetDisconnect)
Parameters
pbTargetDisconnect
Returns last set Target Disconnect status.
Remarks
The GetTargetDisconnectOption method returns the last set Target
Disconnect status.
SetCompleteTransactionOption (bCompleteTransaction )
Parameters
bCompleteTransaction
Specifies the Master completion status on time out at next Run.
TRUE: The TA completes the current transaction as
soon as possible after GNT# is deasserted.
FALSE: The TA continues to complete the transaction
for however many clocks it takes regardless of GNT#
being deasserted.
GetCompleteTransactionOption (pbCompleteTransaction )
Parameters
pbCompleteTransaction
Returns the last set Master completion status.
SetAssertFrameOption(pbAssertFrame)
Parameters
bAssertFrame
Specifies Assertion Status of Frame Signal for TA board for next Run.
FALSE: Asserts the frame and starts the transaction
regardless of the status of the GNT#.
TRUE: Requests the bus and starts the transaction only
after the GNT# is asserted.
GetAssertFrameOption(pbAssertFrame)
Parameters
pbAssertFrame
Returned Assertion Status of last set Frame Signal.
Remarks
SetMasterAbortOption (bMasterAbort)
Parameters
bMasterAbort
Specifies the duty cycle of TA Board on Master Abort.
TRUE: The TA will issue a Master ABORT on the 5th
clock if no DEVSEL# is asserted.
FALSE: The FRAME# will stay asserted indefinitely
and the TA will not issue a Master ABORT.