GetTargetDisconnectOption (pbTargetDisconnect)

Parameters

pbTargetDisconnect

Returns last set Target Disconnect status.

Remarks

The GetTargetDisconnectOption method returns the last set Target
Disconnect status.

SetCompleteTransactionOption (bCompleteTransaction )

Parameters

bCompleteTransaction

Specifies the Master completion status on time out at next Run.

TRUE: The TA completes the current transaction as
soon as possible after GNT# is deasserted.
FALSE: The TA continues to complete the transaction
for however many clocks it takes regardless of GNT#
being deasserted.

GetCompleteTransactionOption (pbCompleteTransaction )

Parameters

pbCompleteTransaction

Returns the last set Master completion status.

SetAssertFrameOption(pbAssertFrame)

Parameters

bAssertFrame

Specifies Assertion Status of Frame Signal for TA board for next Run.

FALSE: Asserts the frame and starts the transaction
regardless of the status of the GNT#.
TRUE: Requests the bus and starts the transaction only
after the GNT# is asserted.

GetAssertFrameOption(pbAssertFrame)

Parameters

pbAssertFrame

Returned Assertion Status of last set Frame Signal.

Remarks

SetMasterAbortOption (bMasterAbort)

Parameters

bMasterAbort

Specifies the duty cycle of TA Board on Master Abort.

TRUE: The TA will issue a Master ABORT on the 5th
clock if no DEVSEL# is asserted.
FALSE: The FRAME# will stay asserted indefinitely