Performance analysis, Real-time, continuous, Statistical (memory capture) – Teledyne LeCroy TA700_800_850 User Manual User Manual
Page 195: Time, Ontinuous, Tatistical, Emory, Apture
TA700/800 SPECIFICATIONS
Catalyst Enterprises, Inc.
181
PERFORMANCE ANALYSIS
Real-time, Continuous
Event Counters
8 counters, each 32 bit.
Count qualifier
Every bus cycle, User defined address space or Sequencer (Based on user
defined sequence of events)
Count Modes
Reset or Accumulative
Count Interval
500 us to 10 minutes
Output Results Reports
Pre-defined
Bus utilization, Efficiencies, Throughput,
Latencies, DMA transfers, Idle time; I/O vs.
Memory utilization.
Custom
Per user defined equations.
Measurement Reports
Normalized to largest per interval or Absolute measurement.
Output Display (Real Time) Text Report, Bar Graph, Pie Chart and histogram.
Display Modes
Color; 2D or 3D
Host CPU interface
Real-time FIFOs
Statistical (Memory Capture)
Capture Depth
User defined up to 128 K
Capture Qualifier
User defined sequence of events.
Measurement types
Min, Max or Average. Number of occurrences. Percentage of
occurrences.
Measurement Qualifiers User-defined address, address range or cycle type.
Report Types
Graphical and Text
Measured Parameters
Latency Target
Latency Master
Latency Arbiter
Efficiency
Target Efficiency
Master Efficiency
Throughput Mb/Sec
Bus Utilization
IDLE
No of Data Transfer/Address
Wait