Get fault number information, Examine management firmware sensors, Analyzing management firmware sensor readings – NEC ExpressA1160 User Manual
Page 193

Get Fault Number Information
10-31
Table 10-7 Explanation of Example Event Log
Event ID
Explanation
1
(Partition level event) At 21:24:02 of 2007-12-12, sensor Cell_0_Pres_Dis (of type = Entity
Presence) entered an event in the event log indicating (asserting) that Cell 0 of the partition
was present.
2
(Partition level event) The same sensor then entered another event indicating that Cell 0 of
the partition, although present, was disabled.
3
(Partition level event) At 21:24:13, the same sensor entered an event indicating that Cell 0
was no longer disabled (that is, its disabled status was de-asserted).
4
(Partition level event) Sensor Partition_Viable (of type = Partition Viability) entered an event
indicating that, as of this moment, the partition was viable (that is, asserting that the
Partition Viability status was asserted). That is, now that Cell 0 is no longer disabled (event
3), the partition is viable.
5
(Partition level event) Sensor Partition_Dgrade (of type = Degraded) entered an event
indicating that the partition was not degraded (that is, asserting that the Partition_Dgrade
status was inactive (de-asserted).
6
(Cell 0 event) FanMod_0_Present (of type = Entity Presence) entered an event indicating
that Fan Module 0 was no longer present (that is, de-asserting that the entity fan 0 was
present).
7
(Cell 0 event) FanMod_1_Present entered the same sort of event.
8
(Cell 0 event) FanMod_0_Present entered an event indicating that Fan Module 0 is now
present.
9
(Cell 0 event) FanMod_1_Present entered an event indicating that Fan Module 1 is now
present.
10
(Partition level event) At 21:53:07, sensor Cell_0_Pres_Dis (same sensor as in events 1–3)
now entered an event indicating that Cell 0 of the partition is still present.
10.8. Get Fault Number Information
NEC service representatives can use the Fsp table converter to get information on a
given fault number.
The interface is described in the Service Guide.
10.9. Examine Management Firmware Sensors
Examining sensor readings might provide additional information that helps when
troubleshooting.
10.9.1. Analyzing
Management Firmware Sensor Readings
The partition remote console interface includes sensor readings. A sensor is an entity