Configuring Alerts using Server Management Software

7-13

monitoring cycle. Transmission errors are caused by heavy network traffic or
defective network devices.

• Click

ok

.

9. Select

Memory

and press Enter.

The Memory Properties window for monitoring functions appears, on which you can
specify the following settings:

• Select

the

Sample Interval

seconds to set the memory monitoring cycle

interval.

• Select

the

Sample Consecutive Number

to set maximum number of

consecutive memory utilization threshold violations.

• Select

Enable Threshold

to activate the memory utilization threshold settings.

• Select values for Fatal and Warning alerts for memory utilization threshold

violations.

• Click

ok

.

10. Select Page Fault and press Enter.

The Page Fault Properties window for monitoring functions appears, on which you
can specify the following settings:

• Select

the

Sample Interval

seconds to set the page fault monitoring cycle

interval.

• Select

the

Sample Consecutive Number

to set maximum number of

consecutive page fault threshold violations.

• Select

Enable Threshold

to activate the page fault threshold settings.

• Select values for Fatal and Warning alerts for page fault threshold violations.

• Click

ok

.

11. Click close to save the settings and close the EXPRESSSCOPE® Monitor for

monitoring functions (ESMagntconf).

To configure alert notifications about report setting functions

1. Start the EXPRESSSCOPE® Monitor for reporting functions (ESMamsadm) by

executing the following command:

# ./ESMamsadm

2. Select

Base Setting

on the Report Setting window, and press Enter.

The Base Setting window appears, in which you specify notification methods.

a. Under

Report

, select the desired notification method, enter values in the

subsequent window, and click ok.