beautypg.com

NEC ExpressA1160 User Manual

Page 140

background image

Configuring Alerts and the SMTP Server using remote console interface

7-6

Figure 7-3 Alert Management - Modify SNMP Trap

Alternatively, click Cancel to return to the Alert Management page without modifying the
alert definition and skip the rest of this procedure.

4. Select

SNMP Trap

or Email from the Alert Type list.

5. Select the minimum severity level from the Event Severity list.

All events having the selected severity level or greater result in the alert being sent.

6. For e-mail alerts, type values for the following:

• Email Address (the destination e-mail address)

• Subject

• Message (the text of the e-mail message)

Refer to

9.4.2 Viewing Alerts Issued by Management Firmware

for an example of

how an alert appears when received.

7. For SNMP trap alerts, type a value for Destination IP Address.

The value is the IP address of the computer on which the background process that
watches for SNMP traps runs.

8. Click

Submit

.

A confirmation dialog box appears.

9. Click

OK

.

The Alert Management page appears displaying the new information.