Clicking the "Comp All" tab causes the setting screen for all channels set to Compressor mode to appear.

(1)

(3)

(4)

(5)

(6)

(7)
(8)

(9)

(1) Mode selection button [Comp/Leveler] (Available only for input channel)

Displays the Compressor/Auto-Leveler mode. Mode selection can be performed for individual channels.
All input channels are set to Compressor mode by default. Clicking this button causes the "Auto-Leveler
mode" or "Compressor mode" to be selected from the pull-down menu.
Note
At the time of mode selection, each parameter of compression and auto-leveler functions for the channel
returns to the initial value.

(2) Input/output level meter

Displays the input/output signal, the reduction (how much the compressor has worked) and the threshold
levels by way of the following bar graph when the unit is operating during communications between the
unit and the PC.

Output signal level

Reduction level

Input signal level

Threshold level