[Gate Settings]
Setting Item
Setting Range
Initial Value
Threshold
–50 to +20 dB, 1 dB steps
–40 dB
Hysteresis
0 to +10 dB, 1 dB steps
0 dB
Depth
–∞, –69 to 0 dB, 1 dB steps
–20 dB
Hold time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300,
10 ms
500, 700, 1000, 2000, 3000, 5000, 10000 ms
Attack time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300,
10 ms
500, 700, 1000, 2000, 3000, 5000, 10000 ms
Release time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300,
10 ms
500, 700, 1000, 2000, 3000, 5000, 10000 ms
ON/OFF
ON, OFF
OFF
[Auto-Leveler Settings]
Setting Item
Setting Range
Initial Value
Target Level
–20 to +10 dB, 1 dB steps
0 dB
Max Gain
0 to +20 dB, 1 dB steps
6 dB
Attack time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300,
500 ms
500, 700, 1000, 1200, 1500, 2000, 2500, 3000,
5000, 7000, 10000 ms
Release time
100, 200, 500, 700, 1000, 1200, 1500, 2000,
1000 ms
2500, 3000, 5000, 7000, 10000 ms
ON/OFF
ON, OFF
OFF
[Auto-Mixing Group Settings]
Setting Item
Setting Range
Initial Value
Auto-Mixing Group
GROUP A, GROUP B, GROUP C, GROUP D
GROUP A
[Compressor Settings]
Setting Item
Setting Range
Initial Value
Threshold
–20 to +20 dB, 1 dB steps
0 dB
Ratio
1 : 1, 1.1 : 1, 1.2 : 1, 1.3 : 1, 1.5 : 1, 1.7 : 1,
1 : 1
2 : 1, 2.3 : 1, 2.6 : 1, 3 : 1, 4 : 1, 5 : 1, 7 : 1,
8 : 1, 10 : 1, 12 : 1, 20 : 1, ∞ : 1
Knee Type
Hard, Soft 1, Soft 2
Hard
Attack time
0.2, 0.5, 0.7, 1.0, 1.5, 2.0, 3.0, 5.0, 7.0, 10, 20,
10 ms
50, 70, 100, 120, 150, 200, 250, 300, 500, 700,
1000, 2000, 3000, 5000 ms
Release time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300,
500 ms
500, 700, 1000, 2000, 3000, 5000 ms
Gain
–∞, –69 to +10 dB, 1 dB steps
0 dB
ON/OFF
ON, OFF
OFF