Toa D-2000 Series User Manual
Page 101
101
7.5.2. Multicast bundle example
In the following connection, the D-2008SP's CobraNet output bundle number must match the CobraNet input
bundle numbers of both CobraNet devices (A) and (B).
D-2008SP
CobraNet device (A)
CobraNet device (B)
Switching hub
CobraNet output
CobraNet output
CobraNet input
CobraNet input
CobraNet input
CobraNet input
PRIMARY
SECONDARY
PRIMARY
SECONDARY
PRIMARY
SECONDARY
7.5.3. CobraNet bundle settings
Perform this setting for the selected unit.
Step 1. Select "Option
CobraNet Module Setting
CobraNet Bundle Setting" from the menu.
The CobraNet Bundle Setting screen is then displayed.
Step 2. Enter the bundle number.
Select 1 – 255 for Multicast bundle and 256 – 65279 for Unicast bundle.
Bundle numbers for two channels (A and B) can be set for both input and output.
Eight-channel audio data is contained in each bundle.
Advanced setting button