beautypg.com

Cobranet module settings – Toa D-2000 Series User Manual

Page 100

background image

100

7.5. CobraNet Module Settings

One of two types of bundle settings to connect the CobraNet equipment to the D-2008SP must be selected:
Unicast and Multicast.
The input and output bundle to be used for the D-2008SP is set to 48 kHz for sampling frequency and 8 for
the number of channels per bundle.
When connecting the D-2008SP to other CobraNet equipment, be sure to match the latency and bit length of
both units.

Note
In the case of the multicast bundle, use 4 bundles or less as it wastes network resources.

7.5.1. Unicast bundle example

In the following connection, the D-2008SP's CobraNet output bundle number must match the CobraNet
device's CobraNet input bundle number.

D-2008SP

CobraNet device

Switching hub

CobraNet output

CobraNet output

CobraNet input

CobraNet input

PRIMARY

SECONDARY

PRIMARY

SECONDARY