7.5. CobraNet Module Settings
One of two types of bundle settings to connect the CobraNet equipment to the D-2008SP must be selected:
Unicast and Multicast.
The input and output bundle to be used for the D-2008SP is set to 48 kHz for sampling frequency and 8 for
the number of channels per bundle.
When connecting the D-2008SP to other CobraNet equipment, be sure to match the latency and bit length of
both units.
Note
In the case of the multicast bundle, use 4 bundles or less as it wastes network resources.
7.5.1. Unicast bundle example
In the following connection, the D-2008SP's CobraNet output bundle number must match the CobraNet
device's CobraNet input bundle number.
D-2008SP
CobraNet device
Switching hub
CobraNet output
CobraNet output
CobraNet input
CobraNet input
PRIMARY
SECONDARY
PRIMARY
SECONDARY