beautypg.com

Setting data samples – Toa D-2000 Series User Manual

Page 154

background image

154

13. SETTING DATA SAMPLES

Setting data samples are contained in the CD supplied with the D-2008SP as files "Gymnasium.d8t,"
"Hall.d8t," and "Changesafe. d8t."
Providing the simple setting examples (data samples) intends to help you make the on-site system design
using the D-2000 Setting Software.

Each data sample is created for the system on the assumption of imaginary facility.
Referring to the sample as an example, make the optimum settings for the actual system depending on the
installation site or unit configuration.
Pay special attention to the Change Safe function setting as incorrect set contents or incorrect operations may
result in such system malfunctions that no sound is output or the sound volume cannot be reduced.

The setting data samples have been set in the following environments.

D-2000 Setting Software: Ver. 4.0.0
D-2008SP firmware:

Ver. 4.0.0

D-2012C firmware:

Ver. 4.0.0

13.1. Setting Example for Use in Gymnasiums

The data sample "Gymnasium.d8t" is a setting example for the system in a gymnasium.

13.1.1. System description

• Includes one D-2008SP and one D-2012C.
• Assumed to be used in an elementary school gymnasium.
• Intended for speech and music playback applications such as lectures or gym classes.
• The sample data is so made to operate the system by simply turning on the power and increasing the input

source fader.

• Memory 2 provides a pattern that speech has precedence over music playback, which is set by a ducker

function in the Automix view. In this pattern, beginning speech automatically decreases BGM volume, and
stopping speech restores the BGM volume to its original level.

• To increase sound clarity for the microphone and wireless microphone inputs, HPF is set in the input Filter

view. To protect these inputs from excessive signals, the Comp function is set.

• To simplify the volume control for CD, MD, and cassette player inputs, the stereo link is set.
• A microphone bus is set up, and the FBS function is set for the bus to prevent feedback.
• Recommended parameters for the speakers to be connected to the speaker output are set in the output

Filter view.

• To protect the speakers from excessive signals, the Comp function is set.
• Channel assignment is made to the D-2012C so that inputs and outputs can be individually controlled.
• Operating the faders of the BGM bus and microphone bus controls the sound volume collectively on each

BGM channel and microphone channel.

• Fader layers are not used.
• A monitor speaker is connected to the monitor output, enabling sound monitoring without actually outputting

sound.

13.1.2. System configuration

• D-2008SP (with three D-2000AD1s and two D-2000DA1s) x 1
• D-2012C x 1
• Main speaker:

ES-0426 x 2

• Sub-speaker:

F-2000B x 2

• Monitor speaker: F-1300B x 1