14.2.10. Settings when the D-2012C is used

[Fader layer settings]

[Console setting view (Function key, motorized fader, and rotary encoder settings)]

Setting Item

Setting Range

Initial Value

Recalling Fader Layer

Layer 1 – 4

Layer 1

Fader Layer Recalled When

Last Layer, Layer 1 – 4

Last Layer

Power is Turned On

Setting Item

Setting Range

Initial Value

Function key

None, Memory, Memory Store, Line Input,

Memory 1 – 6,

LED Control, Fader Layer, Console Switch

Memory Store,

(Contact Output), Key Lock, Monitor Clear

Key Lock

Motorized Fader

None, Audio In, CobraNet In, Audio Bus, Ext. In, – – –
CobraNet Bus, Audio Out, CobraNet Out

Rotary Encoder

None, Audio In, CobraNet In, Audio Bus, Ext. In, – – –
CobraNet Bus, Audio Out, CobraNet Out

[Console SEL/MONI link settings]

Setting Item

Setting Range

Initial Value

Enable SEL/MONI Link

Enabled, Disabled

Disabled

Console ID to link (ID 1 – ID 4)

Enabled, Disabled

Disabled

14.2.11. Security settings

Setting Item

Setting Range

Initial Value

Enable User Level

Enabled, Disabled

Disabled

Create and Delete Unit, Change Unit

Off, Low, Mid, High

Off

Unit Naming, Memory Setting

Off, Low, Mid, High

Off

Store to Memories

Off, Low, Mid, High

Off

Change Safe Setting

Off, Low, Mid, High

Off

14.2.12. Change Safe setting

Setting Item

Setting Range

Initial Value

Enable the "Change Safe" function

Enabled, Disabled

Disabled

Channel Setting

None, a, b, c, d

None

Memory Setting

a, b, c, d (permits multiple selection)