Rockwell Automation Publication 7000-UM151E-EN-P - January 2013

Chapter 5 Drive Programming and Parameters

Invalid codes prompt the following error message:

Figure 182 - Invalid Tag Code

When you have a valid tag code, press [Enter] to continue.

If you select a read-only parameter code, you cannot exit the screen with this read-
only parameter. Type a new code or press [F10] to return to the previous screen
without making a selection.

Figure 183 - Selected Tag Read-only

Text Editing

Several operations require text entry, including:

• setting external faults
• adding text to selected Top Level Menu meters
• identifying the drive with a text string
• entering a filename

The keypad does not contain any alpha keys for text. Use the following
procedures for text entry.

Screens requiring text entry have the F3, F4, and F5 keys in common. Use the
cursor keys to move to the editing field; the screen highlights the text entry field
when active.

Use

or

to move to the next position in the field. Press

or

to cycle

through the character sets in each position. (Note that from the first character of
a set, pressing

wraps immediately to the last character of the set.)