Chapter 4 Initial Operator Interface Configuration

Some operations share common screens, shown only once on the chart and
indicated by symbols inserted into a circle. For example: the ACCESS screen is
available from the MAINMENU by pressing [F10]. In this location (marked by
an *), the ACCESS and PASSWORD CHANGE screens appear in their
entirety. These operations are also available from the MODIFY PARAMETER
and SETUP screens by pressing [F8]. At these locations, screen operation is
represented by the symbol 'P', representing the same flow as previously defined.

The soft function keys that calls the HELP and ALARMS screens are not shown.
All screens can call either function using [F1] and [F6] respectively.

As an example of using the chart, we will modify a parameter while displaying it,
starting from the top-level menu referred to in the chart as the MAINMENU
screen. This example concentrates more on the flow of screens and how it relates
to the chart, rather then the actual function of each screen. The symbols refer to
those of the chart. Descriptions of movement, i.e. lateral, refer to flow depicted on
the chart.

From the MAINMENU, press [F4] to open the DISPLAY GROUP screen.
Scroll to a parameter group and press [Enter]. This laterally moves us to the
DISPLAY screen. Since you selected a parameter group, pressing [F7] opens a
selection operation (symbol 'D') in which the SELECT screen appears, enabling
you to use the cursor keys to select a parameter.

Pressing [Enter] laterally moves us to the symbol T. ending the selection process.
For this example, the symbol T laterally moves to the symbol M that defines a
new parameter modification process. The MODIFY PARAMETER screen
appears.

To modify the parameter, you must have the correct access to it. Press [F8] to call
the ACCESS screen, represented by the symbol P. Select the correct access level
on this screen and press [F10] to exit. This returns to the MODIFY
PARAMETER screen. When you are finished editing the parameter, press [F10]
to return to the SELECT screen (via symbols M and T). Pressing [F10] again
returns to the DISPLAY screen (via the symbol D). Pressing [F10] again will
return you to the DISPLAY GROUP and finally to either the MAINMENU or
the MESSAGE screens.

If you have modified any drive data, pressing [F10] calls the MESSAGE screen
with a prompt to save changes permanently to NVRAM. To leave changes as
temporary, press [F9] for 'No' and continue to the MAINMENU. If you press
[F8] for 'Yes', the NVRAM screen appears, and you can save the data. Exiting the
NVRAM screen returns to the MAINMENU. Pressing [F10] key on the
MESSAGE screen will returns to the DISPLAY GROUP screen.