beautypg.com

Non-isolated process outputs, Auxiliary +24v power supply, Replacing the acb analog control board – Rockwell Automation 7000 PowerFlex Medium Voltage AC Drive (B Frame) - ForGe Control (PanelView 550) User Manual

Page 131

background image

Rockwell Automation Publication 7000-UM151E-EN-P - January 2013

131

Component Definition and Maintenance Chapter 3

Non-Isolated Process Outputs

The drive supplies four non-isolated -10/0/+10 V outputs for customer use.
These outputs can drive loads with impedances as low as 600 ohms. These
outputs are referenced to the Drive AGND; isolate them if you require them to
drive outside the frame enclosure.

Figure 97 - Non-isolated configurable ACB analog outputs

Auxiliary +24V Power Supply

The DC/DC converter has a built-in isolated 24V power supply (Connector P3).
Use this supply for any equipment requiring up to 24 watts at +24 volts. You can
also use it to power any custom drive options, such as isolation modules for
additional Process Control Outputs. The health of this power supply is
monitored in the drive.

Replacing the ACB Analog Control Board

To replace the ACB Analog Control Boards:

1. Isolate and lock out all power to the drive.
2. Remove the transparent sheet on top of the Drive Processor Module and

the Drive Processor Module itself before removing the ACB. Remove the
transparent sheet on top of the DPM by removing the 4 screws.

A/D

DSP

FPGA

27,31,35,39

Analog
Output

25,29,33,37

28,32,36,40

IFM Pin#

PIN NO.

DESCRIPTION

1

ISOLATOR (+24V, 1A)

2

ISOL_COMM (com4)

3

EARTH