SECTION 6 - JLG CONTROL SYSTEM
6-58
– JLG Lift –
3121448
SETUP 6 - LOAD SENS (LSS CALIBRATION)
This menu allows the Calibration Menu is used with Plat-
form weight.
A NEW LOAD CELL OR A NEW LSS MODULE WILL ACT AS IF IT IS
WITHOUT AREA UNTIL THE FOLLOWING PROCEDURE IS PER-
FORMED. THE UPPER FRAME COULD INTERFER WITH THE OUT-
RIGGERS.
THE LOAD SENSING SYSTEM REQUIRES PERIODIC
FUNCTION. VERIFICATION
.
Empty the platform to allow the Load Sensing System to
record its weight during calibration.
Remove the remote control from the basket and keep it on
hand.
1. Press button 6 "SERVICE"
2. Press button 7 "SETUP“.
3. Press button 5 “PASSWORD”.
Using the remote control buttons to enter the pass-
word 6138.
Once the correct password is accepted the display
shown “OK”.
4. Press button 9 “ESC”.
Repeat the above steps if “NO” appear on the dis-
play.
5. Press button 6 “LOADSENS” to enter in LOADSENS
SETUP.
6. Press button 1 “SET 0KG” and wait for about 5 sec-
onds.