JLG X23J - X700AJ Service Manual User Manual
Page 518

SECTION 6 - JLG CONTROL SYSTEM
3121448
– JLG Lift –
6-29
GND/NAV A
ON
The remote control position selector is positioned on “basket”
OFF
The remote control position selector is positioned on “ground”
MICROJIB A
ON
The JIB is closed – the control switch is released and “A” line is closed
OFF
The JIB is open – the control switch is pressed and “A” line is open
MICROJIB B
ON
The JIB is closed – the control switch is released and “B” line is closed
OFF
The JIB is open – the control switch is pressed and “B” line is open
PEDAL
ON
The pedal is pressed– the pedal electric line is closed
OFF
The pedal is released – the pedal electric line is open
FREE B
Do not consider this signal
EMNAV A
ON
The emergency stop on remote control in basket is released – “A” line is closed
OFF
The emergency stop on remote control in basket is pressed or the ground remote
control is disconnected – “A” line is open
EMNAV B
ON
The emergency stop on remote control in basket is released – “B” line is closed
OFF
The emergency stop on remote control in basket is pressed or the ground remote
control is disconnected – “B” line is open
POSM1 A
ON
Outrigger no. 1 is in “reduced area” (or total) – the control switch is released and
“A” line is closed
OFF
Outrigger no. 1 is in “closed” position – the control switch is released and “A” line is
open
POSM1 B
ON
Outrigger no. 1 is in “reduced area” (or total) – the control switch is released and
“B” line is closed
OFF
Outrigger no. 1 is in “closed” position – the control switch is released and “B” line is
open
POSM2 A
ON
Outrigger no. 2 is in “reduced area” (or total) – the control switch is released and
“A” line is closed
OFF
Outrigger no. 2 is in “closed” position – the control switch is released and “A” line is
open
POSM2 B
ON
Outrigger no. 2 is in “reduced area” (or total) – the control switch is released and
“B” line is closed
OFF
Outrigger no. 2 is in “closed” position – the control switch is released and “B” line is
open
POSM3 A
ON
Outrigger no. 3 is in “reduced area” (or total) – the control switch is released and
“A” line is closed
OFF
Outrigger no. 3 is in “closed” position – the control switch is released and “A” line is
open
POSM3 B
ON
Outrigger no. 3 is in “reduced area” (or total) – the control switch is released and
“B” line is closed
OFF
Outrigger no. 3 is in “closed” position – the control switch is released and “B” line is
open
X14J - X19J - X23J - X390AJ - X550AJ - X700AJ