JLG X23J - X700AJ Service Manual User Manual
Page 349

SECTION 3 - CHASSIS & TURNTABLE
3-322
– JLG Lift –
3121448
Malfunction
Indication
Possible cause
Remedial action
Starter con-
tinues to turn
after switch
has been
released.
Noise of starter
turning.
Preheat/starting switch
does not return auto-
matically from position 2
to position 1.
Reset the preheat/start-
ing switch to 0 by force
if necessary and renew
it. If this is not possible,
dis connect the battery
immediately.
Warning!
If this action is not
taken within 2 - 3
minutes, the starter
will overheat and burn
out.
Engine starts
reluctantly or
not at all
although
starter turns
quickly.
Defective preheat
sys tem (this is only
of significance at
temperatures below
-10°C).
Check the preheat
circuit, renew defective
parts if necessary.
This manual is related to the following products: